Системная гипертензия у собак и кошек: литература

Binns SH, Sisson DD, Buoscio DA, et al: Doppler ultrasonographic, oscillometric sphygmomanometric, and photoplethysmographic techniques for noninvasive blood pressure measurement in anesthetized cats. J Vet Intern Med 9:405, 1995. A critical appraisal of the utility of indirect techniques in cats, emphasizing the utility of photoplethysmography in anesthetized cats.

Coulter D, Keith J: Blood pressures obtained by indirect measurement in conscious dogs. J Am Vet Med Assoc 184:1375, 1984. The results of the application of the oscillometric technique to normal dogs and to dogs with various abnormalities, including chronic renal failure, demonstrating the ability of this technique to detect expected changes.

Cowgill LD, Kallet AJ: Recognition and management of hypertension in the dog. In: Kirk RW, ed: Current Veterinary Therapy VIII. Philadelphia, WB Saunders, 1983, p 1025. A review of the diagnosis and management of systemic hypertension in dogs with various clinical conditions.

Grandy JL, Dunlop CI, Hodgson DS, et al: Evaluation of the Doppler ultrasonic method of measuring systolic arterial blood pressure in cats. Am J Vet Res 53:1166, 1992. An evaluation of the Doppler indirect technique for the diagnosis of systemic hypertension in cats.

Labato MA, Ross LA: Diagnosis and management of hypertension. In: August JR, ed: Consultations in Feline Internal Medicine. Philadelphia, WB Saunders, 1991, p 301. A review of the diaffiosis and management of systemic hypertension in cats.

Remillard RL, Ross JN, Eddy JB: Variance of indirect blood pressure measurements and prevalence of hypertension in clinically normal dogs. Am J Vet Res 52:561,1991. A evaluation of the effects of the measurement of blood pressure in the clinical setting versus at home.

Snyder PS, Henik RA: Feline systemic hypertension. Proceedings of the twelfth annual Veterinary Medicine Forum. San Francisco, 1994, р 126. An overview of the pathophysiology and management of systemic hypertension.

Tabaru H, Watanabe H, Tanaka M, et al: Non-invasive measurement of systemic arterial pressure by Finapres in anesthetized dogs. Jpn J Vet Sci 52:427, 1990, Measurement of blood pressure with photoplethysmography in dogs.

Valtonen MH, Eriksson LM: The effect of cuff width and accuracy of indirect measurement of blood pressure in dogs. Res Vet Sci 11:258, 1970. An evaluation of the effects of cuff width on the reliability of indirect blood pressure measurements in dogs.

Ссылки: